Clinical Trial: Tethered Capsule Endoscope in Screening Patients With Barrett Esophagus

Study Status: Recruiting
Recruit Status: Recruiting
Study Type: Interventional

Official Title: Use of a Tethered Capsule Endoscope in Screening for Barrett's Esophagus

Brief Summary: This pilot clinical trial studies how well tethered capsule endoscope works in screening patients with Barrett esophagus (BE), a condition where the lining of the esophagus has changed or has been replaced with abnormal cells that may lead to cancer also called esophageal cancer. In an attempt to prevent the progression from BE to esophageal cancer, patients undergo a standard procedure called esophagogastroduodenoscopy (EGD) where patients are sedated and the doctor uses an endoscope to examine the tissue in the esophagus. Tethered capsule endoscope is a tiny capsule with a laser scan inside and a very thin cord attached to it. Patients swallow the capsule and the thin cord keeps the capsule in specific area in the esophagus. After pictures of the lining of esophagus are taken, the capsule is removed using the thin cord. Tethered capsule endoscope may be able to identify tissue changes in patients with BE without the need for sedation or anesthesia, thus eliminating the associated risks and costs associated with EGD.

Detailed Summary:

PRIMARY OBJECTIVES:

I. Evaluate image quality and usability of the tethered capsule endoscope after repeated clinical use and reprocessing.

II. Evaluate safety issues associated with the use of the device for this subject population - was there any noticeable difference from prior study of subjects at high risk of Barrett's esophagus using the same device, but without reprocessing.

SECONDARY OBJECTIVES;

I. Study other specified device characteristics or device application considerations.

II. Obtain preliminary data for use in designing a subsequent pivotal study of the device.

OUTLINE:

Patients swallow the tethered capsule endoscope (TCE) and undergo endoscopic examination while they are seated on a standard endoscopy gurney. Patients undergo standard of care EGD on the same day.


Sponsor: University of Washington

Current Primary Outcome:

  • Consistent image quality [ Time Frame: At the conclusion of TCE exam (day 1) ]
    Consistent image quality defined as no significant degradation of lateral spatial resolution [line pairs per mm] and axial depth of focus [mm], maximum field of view [degrees cone angle], and color fidelity [qualitatively matches color chart] when measured after use in the clinic using color and resolution test targets and a test chamber to measure field of view. The standard care EGD will be digitally recorded to allow for review and comparison to the TCE procedure by a blinded, expert endoscopist.
  • Consistent usability defined as no significant change to the tolerance rating given by the patient by survey, and ease of use by the physician by survey, and time for completing the examination [ Time Frame: At the conclusion of TCE exam (day 1) ]
  • Incidence of adverse events associated with TCE use [ Time Frame: Up to 1 year ]


Original Primary Outcome: Same as current

Current Secondary Outcome:

Original Secondary Outcome:

Information By: University of Washington

Dates:
Date Received: March 25, 2016
Date Started: July 2016
Date Completion:
Last Updated: February 7, 2017
Last Verified: February 2017